Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ultrasound Med Biol ; 49(10): 2264-2272, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37482477

RESUMO

OBJECTIVE: The aims of the work described here were to assess shear wave attenuation (SWA) in volunteers and patients with non-alcoholic fatty liver disease (NAFLD) and compare its diagnostic performance with that of shear wave dispersion (SWD), magnetic resonance imaging (MRI) proton density fat fraction (PDFF) and biopsy. METHODS: Forty-nine participants (13 volunteers and 36 NAFLD patients) were enrolled. Ultrasound and MRI examinations were performed in all participants. Biopsy was also performed in patients. SWA was used to assess histopathology grades as potential confounders. The areas under curves (AUCs) of SWA, SWD and MRI-PDFF were assessed in different steatosis grades by biopsy. Youden's thresholds of SWA were obtained for steatosis grading while using biopsy or MRI-PDFF as the reference standard. RESULTS: Spearman's correlations of SWA with histopathology (steatosis, inflammation, ballooning and fibrosis) were 0.89, 0.73, 0.62 and 0.31, respectively. Multiple linear regressions of SWA confirmed the correlation with steatosis grades (adjusted R2 = 0.77, p < 0.001). The AUCs of MRI-PDFF, SWA and SWD were respectively 0.97, 0.99 and 0.94 for S0 versus ≥S1 (p > 0.05); 0.94, 0.98 and 0.78 for ≤S1 versus ≥S2 (both MRI-PDFF and SWA were higher than SWD, p < 0.05); and 0.90, 0.93 and 0.68 for ≤S2 versus S3 (both SWA and MRI-PDFF were higher than SWD, p < 0.05). SWA's Youden thresholds (Np/m/Hz) (sensitivity, specificity) for S0 versus ≥S1, ≤S1 versus ≥S2 and ≤S2 versus S3 were 1.05 (1.00, 0.92), 1.37 (0.96, 0.96) and 1.51 (0.83, 0.87), respectively. These values were 1.16 (1.00, 0.81), 1.49 (0.91, 0.82) and 1.67 (0.87, 0.92) when considering MRI-PDFF as the reference standard. CONCLUSION: In this pilot study, SWA increased with increasing steatosis grades, and its diagnostic performance was higher than that of SWD but equivalent to that of MRI-PDFF.


Assuntos
Hepatopatia Gordurosa não Alcoólica , Humanos , Hepatopatia Gordurosa não Alcoólica/complicações , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Fígado/diagnóstico por imagem , Fígado/patologia , Projetos Piloto , Imageamento por Ressonância Magnética/métodos , Ultrassonografia/métodos , Prótons
2.
Artigo em Inglês | MEDLINE | ID: mdl-36318570

RESUMO

Attenuation maps or measurements based on the local attenuation coefficient slope (ACS) in quantitative ultrasound (QUS) have shown potential for the diagnosis of liver steatosis. In liver cancers, tissue abnormalities and tumors detected using ACS are also of interest to provide new image contrast to clinicians. Current phantom-based approaches have the limitation of assuming a comparable speed of sound between the reference phantom and insonified tissues. Moreover, these methods present the inconvenience for operators to acquire data on phantoms and patients. The main goal was to alleviate these drawbacks by proposing a methodology for constructing phantom-free regularized (PF-R) local ACS maps and investigate the performance in both homogeneous and heterogeneous media. The proposed method was tested on two tissue-mimicking media with different ACS constructed as homogeneous phantoms, side-by-side and top-to-bottom phantoms, and inclusion phantoms with different attenuations. Moreover, an in vivo proof-of-concept was performed on healthy, steatotic, and cancerous human liver datasets. Modifications brought to previous works include: 1) a linear interpolation of the power spectrum in the log scale; 2) the relaxation of the underlying hypothesis on the diffraction factor; 3) a generalization to nonhomogeneous local ACS; and 4) an adaptive restriction of frequencies to a more reliable range than the usable frequency range. Regularization was formulated as a generalized least absolute shrinkage and selection operator (LASSO), and a variant of the Bayesian information criterion (BIC) was applied to estimate the Lagrangian multiplier on the LASSO constraint. In addition, we evaluated the proposed algorithm when applying median filtering before and after regularization. Tests conducted showed that the PF-R yielded robust results in all tested conditions, suggesting potential for additional validation as a diagnosis method.


Assuntos
Algoritmos , Imagens de Fantasmas , Ultrassonografia , Humanos , Teorema de Bayes , Som , Ultrassonografia/métodos
3.
PLoS One ; 17(1): e0262291, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35085294

RESUMO

OBJECTIVE: To develop a quantitative ultrasound (QUS)- and elastography-based model to improve classification of steatosis grade, inflammation grade, and fibrosis stage in patients with chronic liver disease in comparison with shear wave elastography alone, using histopathology as the reference standard. METHODS: This ancillary study to a prospective institutional review-board approved study included 82 patients with non-alcoholic fatty liver disease, chronic hepatitis B or C virus, or autoimmune hepatitis. Elastography measurements, homodyned K-distribution parametric maps, and total attenuation coefficient slope were recorded. Random forests classification and bootstrapping were used to identify combinations of parameters that provided the highest diagnostic accuracy. Receiver operating characteristic (ROC) curves were computed. RESULTS: For classification of steatosis grade S0 vs. S1-3, S0-1 vs. S2-3, S0-2 vs. S3, area under the receiver operating characteristic curve (AUC) were respectively 0.60, 0.63, and 0.62 with elasticity alone, and 0.90, 0.81, and 0.78 with the best tested model combining QUS and elastography features. For classification of inflammation grade A0 vs. A1-3, A0-1 vs. A2-3, A0-2 vs. A3, AUCs were respectively 0.56, 0.62, and 0.64 with elasticity alone, and 0.75, 0.68, and 0.69 with the best model. For classification of liver fibrosis stage F0 vs. F1-4, F0-1 vs. F2-4, F0-2 vs. F3-4, F0-3 vs. F4, AUCs were respectively 0.66, 0.77, 0.72, and 0.74 with elasticity alone, and 0.72, 0.77, 0.77, and 0.75 with the best model. CONCLUSION: Random forest models incorporating QUS and shear wave elastography increased the classification accuracy of liver steatosis, inflammation, and fibrosis when compared to shear wave elastography alone.


Assuntos
Hepatite B Crônica/patologia , Inflamação/patologia , Cirrose Hepática/patologia , Fígado/patologia , Hepatopatia Gordurosa não Alcoólica/patologia , Adulto , Idoso , Área Sob a Curva , Doença Crônica , Técnicas de Imagem por Elasticidade/métodos , Estudos de Avaliação como Assunto , Feminino , Humanos , Aprendizado de Máquina , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Ultrassonografia/métodos , Adulto Jovem
4.
Med Phys ; 49(3): 1759-1775, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35045186

RESUMO

BACKGROUND: Noninvasive vascular strain imaging under conventional line-by-line scanning has a low frame rate and lateral resolution and depends on the coordinate system. It is thus affected by high deformations due to image decorrelation between frames. PURPOSE: To develop an ultrafast time-ensemble regularized tissue-Doppler optical-flow principal strain estimator for aorta deformability assessment in a long-axis view. METHODS: This approach alleviated the impact of lateral resolution using image compounding and that of the coordinate system dependency using principal strain. Accuracy and feasibility were evaluated in two aorta-mimicking phantoms first, and then in four age-matched individuals with either a normal aorta or a pathological ascending thoracic aorta aneurysm (TAA). RESULTS: Instantaneous aortic maximum and minimum principal strain maps and regional accumulated strains during each cardiac cycle were estimated at systolic and diastolic phases to characterize the normal aorta and TAA. In vitro, principal strain results matched sonomicrometry measurements. In vivo, a significant decrease in maximum and minimum principal strains was observed in TAA cases, whose range was respectively 7.9 ± 6.4% and 8.2 ± 2.6% smaller than in normal aortas. CONCLUSIONS: The proposed principal strain estimator showed an ability to potentially assess TAA deformability, which may provide an individualized and reliable evaluation method for TAA rupture risk assessment.


Assuntos
Aorta Torácica , Aneurisma da Aorta Torácica , Aorta/diagnóstico por imagem , Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Estudos de Viabilidade , Humanos , Ultrassonografia
5.
Proc Natl Acad Sci U S A ; 117(25): 14453-14463, 2020 06 23.
Artigo em Inglês | MEDLINE | ID: mdl-32513717

RESUMO

Deep regions of the brain are not easily accessible to investigation at the mesoscale level in awake animals or humans. We have recently developed a functional ultrasound (fUS) technique that enables imaging hemodynamic responses to visual tasks. Using fUS imaging on two awake nonhuman primates performing a passive fixation task, we constructed retinotopic maps at depth in the visual cortex (V1, V2, and V3) in the calcarine and lunate sulci. The maps could be acquired in a single-hour session with relatively few presentations of the stimuli. The spatial resolution of the technology is illustrated by mapping patterns similar to ocular dominance (OD) columns within superficial and deep layers of the primary visual cortex. These acquisitions using fUS suggested that OD selectivity is mostly present in layer IV but with extensions into layers II/III and V. This imaging technology provides a new mesoscale approach to the mapping of brain activity at high spatiotemporal resolution in awake subjects within the whole depth of the cortex.


Assuntos
Mapeamento Encefálico/métodos , Córtex Visual/fisiologia , Vigília/fisiologia , Animais , Dominância Ocular/fisiologia , Feminino , Macaca mulatta , Masculino , Estimulação Luminosa , Reprodutibilidade dos Testes , Análise Espaço-Temporal , Ultrassonografia/métodos , Córtex Visual/diagnóstico por imagem
6.
Ultrasound Med Biol ; 46(7): 1715-1726, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32381381

RESUMO

Shear wave elastography (speed and dispersion), local attenuation coefficient slope and homodyned-K parametric imaging were used for liver steatosis grading. These ultrasound biomarkers rely on physical interactions between shear and compression waves with tissues at both macroscopic and microscopic scales. These techniques were applied in a context not yet studied with ultrasound imaging, that is, monitoring steatosis of force-fed duck livers from pre-force-fed to foie gras stages. Each estimated feature presented a statistically significant trend along the feeding process (p values <10-3). However, whereas a monotonic increase in the shear wave speed was observed along the process, most quantitative ultrasound features exhibited an absolute maximum value halfway through the process. As the liver fat fraction in foie gras is much higher than that seen clinically, we hypothesized that a change in the ultrasound scattering regime is encountered for high-fat fractions, and consequently, care has to be taken when applying ultrasound biomarkers to grading of severe states of steatosis.


Assuntos
Patos , Técnicas de Imagem por Elasticidade , Fígado/diagnóstico por imagem , Ultrassonografia , Animais , Técnicas de Imagem por Elasticidade/métodos , Técnicas de Imagem por Elasticidade/veterinária , Nutrição Enteral/veterinária , Fígado Gorduroso/diagnóstico por imagem , Fígado Gorduroso/veterinária , Fígado/anatomia & histologia , Ultrassonografia/métodos , Ultrassonografia/veterinária
7.
Artigo em Inglês | MEDLINE | ID: mdl-30990181

RESUMO

Change in viscoelastic properties of biological tissues may often be symptomatic of a dysfunction that can be correlated to tissue pathology. Shear wave elastography is an imaging method mainly used to assess stiffness but with the potential to measure viscoelasticity of biological tissues. This can enable tissue characterization; and thus, can be used as a marker to improve diagnosis of pathological lesions. In this study, a frequency-shift method based framework is presented for the reconstruction of viscosity by analyzing the spectral properties of acoustic radiation force-induced shear waves. The aim of the study was to investigate the feasibility of viscosity reconstruction maps in homogeneous as well as heterogeneous samples. Experiments were performed in four in vitro phantoms, two ex vivo porcine liver samples, two ex vivo fatty duck liver samples, and one in vivo fatty goose liver. Successful viscosity maps were reconstructed in homogeneous and heterogeneous phantoms with embedded mechanical inclusions having different geometries. Quantitative values of viscosity obtained for two porcine liver tissues, two fatty duck liver samples, and one goose fatty liver were (mean ± SD) 0.61 ± 0.21, 0.52 ± 0.35; 1.28 ± 0.54, 1.36 ± 0.73, and 1.67 ± 0.70 Pa.s, respectively.

8.
Nat Commun ; 10(1): 1400, 2019 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-30923310

RESUMO

Neuroimaging modalities such as MRI and EEG are able to record from the whole brain, but this comes at the price of either limited spatiotemporal resolution or limited sensitivity. Here, we show that functional ultrasound imaging (fUS) of the brain is able to assess local changes in cerebral blood volume during cognitive tasks, with sufficient temporal resolution to measure the directional propagation of signals. In two macaques, we observed an abrupt transient change in supplementary eye field (SEF) activity when animals were required to modify their behaviour associated with a change of saccade tasks. SEF activation could be observed in a single trial, without averaging. Simultaneous imaging of anterior cingulate cortex and SEF revealed a time delay in the directional functional connectivity of 0.27 ± 0.07 s and 0.9 ± 0.2 s for both animals. Cerebral hemodynamics of large brain areas can be measured at high spatiotemporal resolution using fUS.


Assuntos
Circulação Cerebrovascular , Cognição/fisiologia , Lobo Frontal/diagnóstico por imagem , Giro do Cíngulo/diagnóstico por imagem , Movimentos Sacádicos/fisiologia , Animais , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Ecoencefalografia , Movimentos Oculares/fisiologia , Lobo Frontal/fisiologia , Neuroimagem Funcional , Giro do Cíngulo/fisiologia , Macaca , Vias Neurais/diagnóstico por imagem , Vias Neurais/fisiologia , Análise e Desempenho de Tarefas , Ultrassonografia Doppler Transcraniana
9.
Phys Med Biol ; 63(24): 245003, 2018 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-30524065

RESUMO

Ultrasound noninvasive vascular elastography (NIVE) has shown its potential to measure strains of carotid arteries to predict plaque instability. When two-dimensional (2D) strain estimation is performed, either in longitudinal or cross-sectional view, only in-plane motions are considered. The motions in elevation direction (i.e. perpendicular to the imaging plane), can induce estimation artifacts affecting the accuracy of 2D NIVE. The influence of such out-of-plane motions on the performance of axial strain and axial shear strain estimations has been evaluated in this study. For this purpose, we designed a diseased carotid bifurcation phantom with a 70% stenosis and an in vitro experimental setup to simulate orthogonal out-of-plane motions of 1 mm, 2 mm and 3 mm. The Lagrangian speckle model estimator (LSME) was used to estimate axial strains and shears under pulsatile conditions. As anticipated, in vitro results showed more strain estimation artifacts with increasing magnitudes of motions in elevation. However, even with an out-of-plane motion of 2.0 mm, strain and shear estimations having inter-frame correlation coefficients higher than 0.85 were obtained. To verify findings of in vitro experiments, a clinical LSME dataset obtained from 18 participants with carotid artery stenosis was used. Deduced out-of-plane motions (ranging from 0.25 mm to 1.04 mm) of the clinical dataset were classified into three groups: small, moderate and large elevational motions. Clinical results showed that pulsatile time-varying strains and shears remained reproducible for all motion categories since inter-frame correlation coefficients were higher than 0.70, and normalized cross-correlations (NCC) between radiofrequency (RF) images were above 0.93. In summary, the performance of LSME axial strain and shear estimations appeared robust in the presence of out-of-plane motions (<2 mm) as encountered during clinical ultrasound imaging.


Assuntos
Artefatos , Estenose das Carótidas/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Movimento (Física) , Artérias Carótidas/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/normas , Humanos , Imagens de Fantasmas
10.
Neuroimage ; 149: 267-274, 2017 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-28167348

RESUMO

3D functional imaging of the whole brain activity during visual task is a challenging task in rodents due to the complex tri-dimensional shape of involved brain regions and the fine spatial and temporal resolutions required to reveal the visual tract. By coupling functional ultrasound (fUS) imaging with a translational motorized stage and an episodic visual stimulation device, we managed to accurately map and to recover the activity of the visual cortices, the Superior Colliculus (SC) and the Lateral Geniculate Nuclei (LGN) in 3D. Cerebral Blood Volume (CBV) responses during visual stimuli were found to be highly correlated with the visual stimulus time profile in visual cortices (r=0.6), SC (r=0.7) and LGN (r=0.7). These responses were found dependent on flickering frequency and contrast, and optimal stimulus parameters for largest CBV increases were obtained. In particular, increasing the flickering frequency higher than 7Hz revealed a decrease of visual cortices response while the SC response was preserved. Finally, cross-correlation between CBV signals exhibited significant delays (d=0.35s +/-0.1s) between blood volume response in SC and visual cortices in response to our visual stimulus. These results emphasize the interest of fUS imaging as a whole brain neuroimaging modality for brain vision studies in rodent models.


Assuntos
Mapeamento Encefálico/métodos , Imageamento Tridimensional/métodos , Ultrassonografia/métodos , Córtex Visual/diagnóstico por imagem , Vias Visuais/diagnóstico por imagem , Animais , Masculino , Ratos , Ratos Long-Evans
11.
J Biomed Opt ; 20(5): 56004, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25970085

RESUMO

Photoacoustic imaging can achieve high-resolution three-dimensional (3-D) visualization of optical absorbers at penetration depths of ∼1 cm in biological tissues by detecting optically induced high ultrasound frequencies. Tomographic acquisition with ultrasound linear arrays offers an easy implementation of single-side access, parallelized, and high-frequency detection, but usually comes with an image quality impaired by the directionality of the detectors. Indeed, a simple translation of the array perpendicular to its median imaging plane is often used, but results both in a poor resolution in the translation direction and strong limited-view artifacts.To improve the spatial resolution and the visibility of complex structures while retaining a planar detection geometry, we introduce, in this paper, a rotate-translate scanning scheme and investigate the performance ofa scanner implemented at 15 MHz center frequency. The developed system achieved a quasi-isotropic uniform 3-D resolution of ∼170 µm over a cubic volume of side length 8.5 mm, i.e., an improvement in the resolution in the translation direction by almost one order of magnitude. Dual-wavelength imaging was also demonstrated with ultrafast wavelength shifting. The validity of our approach was shown in vitro. We discuss the ability to enable in vivo imaging for preclinical and clinical studies.


Assuntos
Aumento da Imagem/instrumentação , Interpretação de Imagem Assistida por Computador/instrumentação , Imageamento Tridimensional/instrumentação , Técnicas Fotoacústicas/instrumentação , Transdutores , Ultrassonografia/instrumentação , Anisotropia , Desenho de Equipamento , Análise de Falha de Equipamento , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Lasers , Imagens de Fantasmas , Reprodutibilidade dos Testes , Rotação , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...